FW-Bus Client
- Connect with FW-Bus Host.
- Can support up to 8 units of the device
- DIP Switch to select the Device ID.
Internal power supply with DC/DC converter to reduce power wastage
- Input DC 12V to 24V.
- Reverse polarity protection.
Onboard Input and Output Port
- 8 input ports and 8 output ports.
- Able to configure the input port as I/O input or user push-button input.
- Push button input can detect single press, double press, triple press, and long press (press and hold more than 4 seconds).
- Provide a number of input on/off cycle counter to prevent missing cycle.
- Wet contact output design using MOSFET thus support up to 30V 1A output current without the wear and tear of the relay contact.
- The output port can be configured as standard High/Low output or Pulsed output.
- Configurable pulse duration (configure separately for High level and Low-level periods) and a number of pulse cycles when triggered by the server.