EV RE-01-0808 (WiRIO3 I/O Extension Unit)

FW-Bus Client

  • Connect with FW-Bus Host.
  • Can support up to 8 units of the device
  • DIP Switch to select the Device ID.

Internal power supply with DC/DC converter to reduce power wastage

  • Input DC 12V to 24V.
  • Reverse polarity protection.

Onboard Input and Output Port

  • 8 input ports and 8 output ports.
  • Able to configure the input port as I/O input or user push-button input.
  • Push button input can detect single press, double press, triple press, and long press (press and hold more than 4 seconds).
  • Provide a number of input on/off cycle counter to prevent missing cycle.
  • Wet contact output design using MOSFET thus support up to 30V 1A output current without the wear and tear of the relay contact.
  • The output port can be configured as standard High/Low output or Pulsed output.
  • Configurable pulse duration (configure separately for High level and Low-level periods) and a number of pulse cycles when triggered by the server.
Dimensions10 × 6.8 × 4 cm
Input Voltage

DC 12V to 24V

System Power Consumption

5W Max

Operation Humidity

20 % ~ 90 % RH

Operation Temp

25°C ~ 45°C

Storage Temp

0°C ~ 85°C

Enclosure Type

ABS

Output Port

8 Channel

Connection Type

N Type Sink to Ground when on

Max V+ Voltage

30V

Max Sink Current Output

1A (Non-Inductive Load)

Input Port

8 Channel

Max Sink Current Input

5mA